Fire Doors in MumbaiSpecified against DCPR 2034, not UDCPR
Valtrix manufactures IS 3614:2021 certified fire doors in Nashik and supplies them to projects across Mumbai. Ratings run from FD30 to FD180 in Fully Insulated, Partially Insulated, Uninsulated and Acoustic doorsets, single and double leaf. Mumbai is the one city in Maharashtra where UDCPR does not apply, so the door schedule is written against DCPR 2034 and the Mumbai Fire Brigade’s own requirements.

Valtrix fire doors in Mumbai: key facts
- Who
- Valtrix Fire Safety Solutions, a product brand of Bhimraj Industries Pvt. Ltd.
- What
- Fire-rated steel doorsets, FD30, FD60, FD90, FD120, FD180
- Standard
- IS 3614:2021 certified; ISO 14001:2015 certified
- Made in
- Dhakambe, Dindori, Nashik, Maharashtra 422004
- Supplies to
- Mumbai and MMR, and projects across India
- Contact
- +91 89561 96974 · valtrixinfo@gmail.com
UDCPR stops at the city limits
Every other city on this site runs on the Unified Development Control and Promotion Regulations. Mumbai does not. The Mumbai Fire Brigade’s own codified requirements point at DCPR 2034 — for staircases, they cite "Regulation 37(15) & 47 of DCPR-2034", and corridor and lift lobby ventilation is required "as per the provisions of DCPR-2034".
That matters when a specification is copied between projects. A door schedule written against a UDCPR clause number means nothing to a Mumbai Fire Brigade officer, and the UDCPR special building test that governs a Pune or Nashik building does not decide a Mumbai one.
What does carry across the whole state is the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, including the twice-yearly maintenance certificate in January and July under Section 3(3), and the IS 3614:2021 standard the doorsets themselves are certified to.
Four openings the Fire Brigade gives a rating to
MCGM publishes codified fire safety requirements by building category. The ones quoted here are from the low-rise residential set, for buildings up to 32 m — taller and non-residential buildings have their own, so confirm which applies to your project before you buy anything.
Duplex flat entrance
"Entrance/Exit doors of the Upper duplex rooms is having Fire rating not less than one hrs." — an FD60 doorset, opening into the protected lift lobby or corridor without hindrance.
Lift doors
"Collapsible gates shall not be permitted for lifts; the lifts shall have solid doors with fire resistance of at least one hour." Again one hour, and solid — a collapsible gate is not an option.
DG set room
"The door of DG Set room is 2 hrs. fire resistance." That is an FD120 doorset, consistent with how plant rooms are treated under NBC 2016.
Car parking structure
"Elements of the car parking structure are 2 hr. fire resistance" and "Each car parking deck is 2 hr. fire resistance" — which sets the rating for openings into those decks.
The staircase itself is specified by reference: layout and flight width "as per Regulation 37(15) & 47 of DCPR- 2034", with a permanent vent at the top equal to 5 per cent of the staircase cross-sectional area, and a smoke check lobby at basement level.
The terrace door is a refuge door, and MFB specifies it exactly
Mumbai treats the terrace as a refuge area, and the door onto it is not an ordinary door. The codified requirements set out three things that have nothing to do with the fire rating and everything to do with whether people get out:
- Louvers: "The top half portion of the doors provided with louvers."
- Latch position: "The latch-lock installed from the terrace side at the height if not more than 1 mtrs."
- Breakable glass: "The glass front of 6 inch diameter with the breakable glass is provided just above the latch lock, so as to open the latch in case of an emergency by breaking glass."
On the refuge area itself: "Terrace floor of the building shall be treated as Refuge Area", the access doors from the enclosed staircase to the terrace must have louvers in the top half, and the entrance doors to the terrace are "painted or fixed with sign painted in luminous paint mentioning REFUGE AREA".
A terrace door bought as a plain rated leaf will not satisfy this. The louver, the latch height, the breakable glass panel and the luminous signage all have to be designed into the doorset, which means they have to be in the enquiry. They also have to sit inside the tested assembly — cutting a louver or a glass port into a certified leaf on site voids the evidence, as verifying a certified fire door explains.
Four kinds of Mumbai project, four different door problems
Mumbai builds vertically and densely, so the compartment line matters more here than almost anywhere else.

Residential towers
Staircase enclosures, lift lobbies, flat entrances, refuge terraces and duplex units. See NBC 2016 fire door requirements for high-rise.

Commercial and data centres
Offices, server rooms and plant rooms where the door has to seal as well as resist fire. See fire doors for data centres.

Hospitals and healthcare
Compartment lines and escape routes needing rated doorsets whose hardware, seals and glazing stay inside the certified assembly. Acoustic doorsets suit wards.

Hotels and institutional
Tender-driven buying with written technical criteria and document checks. Read why fire door technical bids get rejected first.
Provisional first, occupation NOC at the end
The Mumbai Fire Brigade sits inside MCGM and is the authority for buildings in city limits. The route is staged, and the second stage is what catches projects out.
Fire protection requirements at plan stage
MFB stipulates the fire protection and firefighting requirements for the proposed building, and issues amendment letters when plans are revised.
Build to those requirements
MFB’s letters note that additional requirements recommended before final occupation must also be complied with — the plan-stage list is a floor, not a ceiling.
Occupation NOC
MFB runs a separate occupation checklist, filled and signed by the architect or licensed surveyor and submitted with the application. The occupancy certificate follows from MCGM.
Tall buildings carry an extra layer. Older MCGM material required a High Rise Committee NOC above 70 m; reporting since then describes the Municipal Commissioner being able to clear taller proposals directly on larger plots. Those thresholds move, so confirm the current position with MCGM rather than with any summary, this one included.
For the door side of an inspection anywhere in Maharashtra, see fire NOC door requirements, and for hardware that has to work on the day, why self-closing is not optional.
Four doorset families, specified to the opening
Each family is available in single and double leaf, with fire-rated vision panels and glass where the specification requires them. Not sure which suits your project? How to choose the right fire door walks through the decision.
What to send for a Mumbai quotation
A door schedule is enough to start. For Mumbai, the terrace and refuge doors are worth calling out separately, because they carry features an ordinary rated leaf does not.
Prices depend on rating, size, glazing, hardware and finish, so we quote against your schedule rather than publish a list. For what drives cost, see fire door price in India.
- Rating per opening: FD30, FD60, FD90, FD120 or FD180
- Doorset family: Fully Insulated, Partially Insulated, Uninsulated or Acoustic
- Leaf type and size: single or double leaf, width and height
- Terrace or refuge doors: louver, latch height, breakable glass port, luminous signage
- Vision panel: required or not, and size
- Hardware and finish: closer, locks, panic hardware, colour
Fire doors in Mumbai: common questions
Does UDCPR apply to fire doors in Mumbai?
No. Mumbai is governed by DCPR 2034. The Mumbai Fire Brigade’s codified requirements cite Regulation 37(15) and 47 of DCPR-2034 for staircases and refer to DCPR-2034 for corridor and lift lobby ventilation. The Maharashtra Fire Prevention and Life Safety Measures Act, 2006 does apply across the state, Mumbai included.
What fire rating does a duplex flat entrance door need in Mumbai?
MCGM’s codified requirements for low-rise residential buildings up to 32 m state that entrance and exit doors of upper duplex rooms have a fire rating of not less than one hour, opening into the protected common lift lobby or corridor without hindrance. One hour is an FD60 doorset.
What rating does a DG set room door need?
The same codified requirements state that the door of the DG set room is 2 hours fire resistance, which is an FD120 doorset. Car parking structure elements and each parking deck are also set at 2 hour fire resistance.
What is special about a Mumbai terrace door?
The terrace floor is treated as a refuge area. The door needs louvers in the top half, a latch-lock fitted on the terrace side at not more than 1 m height, and a 6 inch breakable glass port just above the latch so it can be opened in an emergency. The terrace entrance doors also carry REFUGE AREA signage in luminous paint.
Can lifts have collapsible gates in a Mumbai building?
No. The codified requirements state that collapsible gates shall not be permitted for lifts, and that lifts shall have solid doors with fire resistance of at least one hour.
Who issues the fire NOC in Mumbai?
The Mumbai Fire Brigade, which sits within MCGM. Fire protection requirements are stipulated at plan stage, and a separate occupation NOC checklist signed by the architect or licensed surveyor is submitted before the occupancy certificate. Thresholds for high-rise committee referral have changed over time, so confirm the current process with MCGM.
How do I get a quotation for fire doors in Mumbai?
Call +91 89561 96974 or message on WhatsApp with your door schedule: rating, leaf type, size, vision panel, hardware, finish and quantity, and flag any terrace or refuge doors separately. Valtrix quotes against the schedule rather than publishing a price list.
Related guides and locations
Last reviewed 2026-11-03. Local requirements and forms change; confirm them with the relevant fire authority.